Impact of Link Failures on the Performance of MapReduce in Data Center Networks

Reading time: 5 minute
...

📝 Original Info

  • Title: Impact of Link Failures on the Performance of MapReduce in Data Center Networks
  • ArXiv ID: 1808.06115
  • Date: 2018-08-21
  • Authors: - 정보 제공되지 않음 (원문에 저자 정보가 명시되지 않음)

📝 Abstract

In this paper, we utilize Mixed Integer Linear Programming (MILP) models to determine the impact of link failures on the performance of shuffling operations in MapReduce when different data center network (DCN) topologies are used. For a set of non-fatal single and multi-links failures, the results indicate that different DCNs experience different completion time degradations ranging between 5% and 40%. The best performance under links failures is achieved by a server-centric PON-based DCN.

💡 Deep Analysis

📄 Full Content

Providing high reliability and continuity is a key requirement for cloud computing services as any disruption or disconnection in the infrastructure typically leads to revenue losses and customer departures. Failures in cloud infrastructure can occur in the transporting networks, data centers, or in the applications [1]. Overcoming the severe impacts of these failures requires the adoption of resilient designs and restoration plans. The resilience and energy efficiency of different IP over WDM networks topologies were examined in [2] under fiber cuts or a core node failure. The work in [3] and [4] considered static and dynamic adaptation to traffic surges resulting from re-routing demands after links failures. In [5], an energy efficient 1+1 protection scheme in IP over WDM networks was proposed based on Network Coding (NC) while considering the impact of the topology and the traffic. The authors in [6] addressed the resilience of geo-distributed transport networks that link cloud data centers by jointly considering the content placement, and anycast routing under failures. At the application level, solutions such as maintaining several replicas of data and software components are considered. For example, MapReduce, which is a widely used framework for big data parallel computations, has a data replication mechanism with default value of 3, and considers speculative execution for straggler tasks [7]. Several studies have considered the resilience of Data Center Networks (DCN) (e.g. [8]- [11]) by addressing the sources of links, switches, and servers' software and hardware failures.

In this paper, we examine single and multi-link non-fatal failures in several DCNs and their effect on the performance of MapReduce shuffling operations. We compare the completion time results in [12] and [13] under no link failures to the results under several link failures for electronic, hybrid, and optical DCNs, in addition to a server-centric Passive Optical Networks (PON)-based DCN design proposed as part of the work in [14]- [19]. The rest of this paper is organized as follows. Section 2 describes the proposed optimization models and shows their results, while Section 3 provides the conclusions and future work.

We utilize Mixed Integer Linear Programming (MILP) models to examine the effects of single and multi-link failures in different DCNs on the optimum routing of intermediate data while balancing the completion time and the energy efficiency. Seven DCNs [12] namely Spine-and-Leaf, Fat-Tree, BCube, DCell, c-Through, Helios, in addition to the server-centric PON-based DCN design in [16] with 4 racks and 1 server per group, are considered. Figure 1 illustrates the assignment of map and reduce workers in 10 and 6 servers, respectively in each DCN model. It also shows the link disconnection cases considered. Indy GraySort benchmark [20] is selected as it is a representative workload for examining the congestion in DCNs due to routing intermediate data that is equal in size to the input data from the 10 map workers to the 6 reduce workers. The power consumption values of the selected electronic and optical equipment are as in [12], and [15].

Figure 2 provides the shuffling completion time results for a maximum server rate of 1000 Mbytes/s and input data ranging from 1 to 20 GBytes in different DCNs. The subfigures, show the results in [12], and [13] for the cases where all links are working, in addition to the completion time results under 2 or 3 cases of links failures in each DCN. For the Spine-and-Leaf architecture, the degradation due to links 1-3 disconnection is less than 2-6 because the latter is more utilized due to serving the flows to 3 reduce workers compared to 1 reduce worker by links 1-3. In the Fat-Tree architecture, we examined the impact of disconnecting the most utilized links (i.e. 17-20). Any additional links disconnections did not deteriorate the performance. In both DCNs, failure in any link between the Top of Rack (ToR) and a server is considered a single point-of-failure and requires a software-based resilience mechanism such as replication, where the map computations should be re-performed in another server containing a replica. The BCube and DCell architectures are server-centric DCNs with two links to each server which provides more routes compared to the Spine-and-Leaf architecture and the Fat-Tree architecture, and hence, are more resilient to link failures. Single and multi-link failures including the most utilized link in BCube caused an increase of 24% in the completion time. The DCell architecture exhibited the highest degradation in the completion time (i.e. 40%) with links 1-6 disconnection which are the most utilized due to serving two reduce workers from other racks, which indicates high sensitivity to workload placements. An average increase by 37% in the completion time is experienced in the c-Through architecture and by 5% in the Helios architecture for three link failures because m

Reference

This content is AI-processed based on open access ArXiv data.