Monte Carlo simulation of carbon ion radiotherapy for Human Eye

Reading time: 2 minute
...

📝 Original Info

  • Title: Monte Carlo simulation of carbon ion radiotherapy for Human Eye
  • ArXiv ID: 1403.0344
  • Date: 2015-06-18
  • Authors: Researchers from original ArXiv paper

📝 Abstract

Carbon ion is the mostly common used particle in heavy ion radiotherapy. In this paper, carbon ion dose in tumor treatment for human eye was simulated with FLUKA code, 80 MeV/u carbon beam was irradiated into the human eye from two directions, The first is from the lateral-forward direction which was a typical therapeutic condition, maximum dose was deposited in the tumor volume. The second one was that beam irradiated into eyes from the forward direction which may cause certain medical accident. The calculated results are compared with other reports. The agreement indicates that this method can be used for treatment plan in heavy ion radiotherapy.

💡 Deep Analysis

Deep Dive into Monte Carlo simulation of carbon ion radiotherapy for Human Eye.

Carbon ion is the mostly common used particle in heavy ion radiotherapy. In this paper, carbon ion dose in tumor treatment for human eye was simulated with FLUKA code, 80 MeV/u carbon beam was irradiated into the human eye from two directions, The first is from the lateral-forward direction which was a typical therapeutic condition, maximum dose was deposited in the tumor volume. The second one was that beam irradiated into eyes from the forward direction which may cause certain medical accident. The calculated results are compared with other reports. The agreement indicates that this method can be used for treatment plan in heavy ion radiotherapy.

📄 Full Content

Carbon ion is the mostly common used particle in heavy ion radiotherapy. In this paper, carbon ion dose in tumor treatment for human eye was simulated with FLUKA code, 80 MeV/u carbon beam was irradiated into the human eye from two directions, The first is from the lateral-forward direction which was a typical therapeutic condition, maximum dose was deposited in the tumor volume. The second one was that beam irradiated into eyes from the forward direction which may cause certain medical accident. The calculated results are compared with other reports. The agreement indicates that this method can be used for treatment plan in heavy ion radiotherapy.

Reference

This content is AI-processed based on ArXiv data.

Start searching

Enter keywords to search articles

↑↓
ESC
⌘K Shortcut