Liquid Metal as Connecting or Functional Recovery Channel for the Transected Sciatic Nerve

Reading time: 4 minute
...

📝 Original Info

  • Title: Liquid Metal as Connecting or Functional Recovery Channel for the Transected Sciatic Nerve
  • ArXiv ID: 1404.5931
  • Date: 2014-04-24
  • Authors: Researchers from original ArXiv paper

📝 Abstract

In this article, the liquid metal GaInSn alloy (67% Ga, 20.5% In, and 12.5% Sn by volume) is proposed for the first time to repair the peripheral neurotmesis as connecting or functional recovery channel. Such material owns a group of unique merits in many aspects, such as favorable fluidity, super compliance, high electrical conductivity, which are rather beneficial for conducting the excited signal of nerve during the regeneration process in vivo. It was found that the measured electroneurographic signal from the transected bullfrog sciatic nerve reconnected by the liquid metal after the electrical stimulation was close to that from the intact sciatic nerve. The control experiments through replacement of GaInSn with the conventionally used Riger Solution revealed that Riger Solution could not be competitive with the liquid metal in the performance as functional recovery channel. In addition, through evaluation of the basic electrical property, the material GaInSn works more suitable for the conduction of the weak electroneurographic signal as its impedance was several orders lower than that of the well-known Riger Solution. Further, the visibility under the plain radiograph of such material revealed the high convenience in performing secondary surgery. This new generation nerve connecting material is expected to be important for the functional recovery during regeneration of the injured peripheral nerve and the optimization of neurosurgery in the near future.

💡 Deep Analysis

Deep Dive into Liquid Metal as Connecting or Functional Recovery Channel for the Transected Sciatic Nerve.

In this article, the liquid metal GaInSn alloy (67% Ga, 20.5% In, and 12.5% Sn by volume) is proposed for the first time to repair the peripheral neurotmesis as connecting or functional recovery channel. Such material owns a group of unique merits in many aspects, such as favorable fluidity, super compliance, high electrical conductivity, which are rather beneficial for conducting the excited signal of nerve during the regeneration process in vivo. It was found that the measured electroneurographic signal from the transected bullfrog sciatic nerve reconnected by the liquid metal after the electrical stimulation was close to that from the intact sciatic nerve. The control experiments through replacement of GaInSn with the conventionally used Riger Solution revealed that Riger Solution could not be competitive with the liquid metal in the performance as functional recovery channel. In addition, through evaluation of the basic electrical property, the material GaInSn works more suitable f

📄 Full Content

In this article, the liquid metal GaInSn alloy (67% Ga, 20.5% In, and 12.5% Sn by volume) is proposed for the first time to repair the peripheral neurotmesis as connecting or functional recovery channel. Such material owns a group of unique merits in many aspects, such as favorable fluidity, super compliance, high electrical conductivity, which are rather beneficial for conducting the excited signal of nerve during the regeneration process in vivo. It was found that the measured electroneurographic signal from the transected bullfrog sciatic nerve reconnected by the liquid metal after the electrical stimulation was close to that from the intact sciatic nerve. The control experiments through replacement of GaInSn with the conventionally used Riger Solution revealed that Riger Solution could not be competitive with the liquid metal in the performance as functional recovery channel. In addition, through evaluation of the basic electrical property, the material GaInSn works more suitable for the conduction of the weak electroneurographic signal as its impedance was several orders lower than that of the well-known Riger Solution. Further, the visibility under the plain radiograph of such material revealed the high convenience in performing secondary surgery. This new generation nerve connecting material is expected to be important for the functional recovery during regeneration of the injured peripheral nerve and the optimization of neurosurgery in the near future.

Reference

This content is AI-processed based on ArXiv data.