Novel detector systems for the Positron Emission Tomography

Reading time: 3 minute
...

📝 Original Info

  • Title: Novel detector systems for the Positron Emission Tomography
  • ArXiv ID: 1305.5187
  • Date: 2013-10-15
  • Authors: Researchers from original ArXiv paper

📝 Abstract

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma quanta. The device is comprised of scintillation chamber consisting of organic scintillators surrounding the body of the patient. We discuss two possible solutions: (i) the tomograph built out of scintillator strips, and (ii) the tomograph built out of the scintillator plates. The application of the fast scintillators will enable to take advantage of the difference between time of the registration of the annihilation quanta. The invented method will permit to use a thick layers of detector material with the possibility of measuring the depth of the gamma quantum interaction (DOI) and the determination of their time of flight (TOF), and will allow for increasing the size of the diagnostic chamber without a significant increase of costs. The method is a subject of two patent applications which are based on the techniques used in the particle physics experiments.

💡 Deep Analysis

Deep Dive into Novel detector systems for the Positron Emission Tomography.

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma quanta. The device is comprised of scintillation chamber consisting of organic scintillators surrounding the body of the patient. We discuss two possible solutions: (i) the tomograph built out of scintillator strips, and (ii) the tomograph built out of the scintillator plates. The application of the fast scintillators will enable to take advantage of the difference between time of the registration of the annihilation quanta. The invented method will permit to use a thick layers of detector material with the possibility of measuring the depth of the gamma quantum interaction (DOI) and the determination of their time of flight (TOF), and will allow for increasing the size of the diagnostic chamber without a significant increase of costs. The method is

📄 Full Content

In this contribution we describe a novel solution for the construction of Positron Emission Tomograph. We present the device allowing for determination of the impact position as well as time and deph of interaction of the annihilation gamma quanta. The device is comprised of scintillation chamber consisting of organic scintillators surrounding the body of the patient. We discuss two possible solutions: (i) the tomograph built out of scintillator strips, and (ii) the tomograph built out of the scintillator plates. The application of the fast scintillators will enable to take advantage of the difference between time of the registration of the annihilation quanta. The invented method will permit to use a thick layers of detector material with the possibility of measuring the depth of the gamma quantum interaction (DOI) and the determination of their time of flight (TOF), and will allow for increasing the size of the diagnostic chamber without a significant increase of costs. The method is a subject of two patent applications which are based on the techniques used in the particle physics experiments.

Reference

This content is AI-processed based on ArXiv data.